Description
RIGRS BOP Hose Scope of application:
RIGRS supplies API 16D BOP control hose assemblies for hydraulic well-control systems used on land and offshore drilling rigs. These hoses are typically installed between the BOP control unit or accumulator system and the hydraulic functions on the BOP stack, diverter or associated well-control equipment.
Hose assemblies can be configurign according to requiring inside diameter, working pressure, overall length, end connection, operating temperature, fire-resistant protection and external armor requirements.
For replacement projects, buyers can send the existing hose marking or nameplate, overall hose photos and clear photos of both end fittings. Our team can review the available information before quotation.
Armored hose assemblies with flame resistant cover withstand minimum 1300°F(+700℃)flame temperature at working pressure for 5 minutes without failure.
Product classification: high molecular polymer jacket type, stainless steel armored jacket type and braided stainless steel wire jacket type.
Get an Instant SCM Quote – RUGRS BOP Hose
Where Is a BOP Control Hose Used?
1. BOP Accumulator Unit to Control Manifold
Flexible hydraulic hose assemblies may be using within the BOP accumulator and control system where flexibility is requiring between hydraulic components. The hose must match the control pressure, hydraulic fluid, connection type and installation routing of the existing system.
2. Control Manifold to BOP Functions
BOP control hoses transmit hydraulic control fluid to functions such as ram preventers, annular preventers and hydraulically operating well-control valves. Hose size, length and routing should be confirming according to the requiring hydraulic response and the existing control-system design.
3. Diverter Control System
API Spec 16D also addresses control systems for diverter equipment. Hose assemblies used in diverter control circuits should be selecting according to system pressure, hydraulic-fluid compatibility, routing and project requirements.
4. Replacement During Rig Maintenance
BOP hoses are commonly replacing during rig overhaul, BOP recertification, control-unit refurbishment or planning preventive maintenance. Replacement selection should not be based on hose diameter alone; pressure rating, end fitting, length, fire protection and installation routing must also be confirming.
We can help check the likely specification before quotation.
BOP Hose Construction and Supply Options
Hydraulic-Fluid-Resistant Inner Tube
The hose inner tube is selected for compatibility with the specified hydraulic control fluid and operating temperature.
High-Tensile Reinforcement
Multiple reinforcement layers provide pressure containment while maintaining the flexibility required for BOP control-system routing.
External Protection
Depending on the application, hose assemblies can be suppling with abrasion-resistant outer protection, stainless-steel braid or armoring protection.
Fire-Resistant Configuration
Fire-resistant insulation can be incorporating where requiring by the purchaser’s BOP control-system specification.
Custom End Fittings
End fittings can be configuring according to the existing control-unit connection, equipment drawing or replacement hose specification.
Serial Identification and Documentation
Hose assemblies can be suppling with identification and inspection documentation according to the confirming purchase specification.
BOP Hose Loop and Flexible Routing
A BOP hose loop provides flexible hydraulic routing between control-system components where rigid tubing cannot accommodate equipment movement, vibration or installation geometry.
Hose-loop design should consider the minimum bend radius, overall hose length, connection orientation, available installation space and expected equipment movement. Excessively short hose assemblies can introduce tensile loading, while excessive length may create unsupported loops, abrasion points or routing interference.
When requesting a BOP hose loop, please provide the installation drawing or the approximate distance between the two connection points, connection orientation and available routing space.
Guidelines for the Use of BOP Hoses at Well Sites
To secure optimal hydraulic response times and preserve the certified validation lifespan under international wellsite audits, field operators must track these engineering boundaries:
- Do not exceed the minimum bend radius specified for the hose.
- Avoid twisting the hose during installation.
- Confirm compatibility between the hose materials and the hydraulic fluid used in the system.
- Inspect hose assemblies regularly for wear, corrosion, leakage or mechanical damage.
- Follow the maintenance procedures recommended by the drilling contractor or equipment manufacturer.
When Should a BOP Hose Be Replaced?
A leaking BOP hose should not be treating as a routine hydraulic-hose issue because the hose forms part of the well-control actuation system. Hose assemblies should be inspecting whenever leakage, cover damage, corrosion, fitting movement or abnormal deformation is observing.
Typical replacement indicators include:
Hydraulic fluid leakage from the hose body or fitting area
Cracks, cuts, blistering or severe abrasion on the outer cover
Corrosion or damage to stainless-steel armor
Loose, damaged or deformed end fittings
Kinking or permanent deformation
Installation below the specified minimum bend radius
Uncertain hose history or missing identification
Failed pressure testing
Replacement required by the operator’s maintenance or inspection program
If the original hose specification is unavailable, send the hose nameplate, full-length photo and end-fitting photos for review.
FAQ – API 16D BOP Hose
Q1: What audit-ready verification paperwork is bundling with your API 16D BOP control hoses?
A: Upon delivery, you receive a full quality binder containing the Official API Spec 16D Certificate of Authority, an individual Factory Acceptance Test (FAT) Report charting a continuous 15-minute pressure hold at 1.5x working pressure, chemical and physical Material Test Reports (MTRs) tracking the forged AISI 4130 unions, and a batch verification log confirming fire test compliance.
Q2: What is your standard factory lead time for a custom-length 1-inch 5,000 PSI BOP line order?
A: For standard industrial internal diameters (1/2″, 3/4″, and 1″ ID), we maintain a comprehensive inventory of bulk raw vulcanized core blanks and forged metal fittings. Standard custom swaging, testing, armor-wrapping, and export packaging require 10 to 15 business days. For emergency rig-down or critical platform startup operations, contact our prioritized logistics office to secure immediate factory line allocation.
Q3: How do you protect large-bore armored hoses against corrosion during long ocean transit or coastal warehouse storage?
A: We manage logistics risks directly. Every hose assembly is fitted with robust steel blanking caps or heavy-duty plastic protectors to seal out humidity. Hoses are coiled precisely to match minimum bend geometries, wrapped completely in heavy water-resistant UV-barrier plastic shrink wrap, and packed securely into export-grade, IPPC-certified fumigated wooden crates lined with active moisture barriers.
Q4: Can we deploy an independent surveyor (e.g., DNV, ABS, SGS) to witness the pressure testing of our project’s hose order?
A: Yes, we support complete third-party transparency. We regularly welcome surveyors from ABS, DNV, Bureau Veritas (BV), or SGS to our internal factory testing laboratories. Supply chain managers can seamlessly align this step with our Quality Control Plan (QCP) milestones to obtain full classification endorsement before the cargo departs our facility.
Q5: Is BOP hose the same as a normal hydraulic hose?
A: No. BOP hose is using in well control systems and may require specific pressure rating, fire resistance, temperature performance, connection type and inspection documents. It should be selected according to the actual BOP control system.
Q6: Can you supply fire-resistant BOP hose?
Yes. Fire-resistant BOP hose can be supplied according to project requirements. Please confirm the fire resistance requirement before quotation.
Q7: What information is needed for quotation?
Please provide working pressure, hose bore, overall length, end connection, control fluid, temperature requirement, fire resistance requirement, quantity and required documents.
Q8: Can the end connections be customized?
Yes. End connections can be supplied according to project requirement, including thread, flange, union, quick coupling or other specified fittings.
Q9: Do you provide pressure test reports?
Yes. Pressure test reports and inspection documents can be provided according to order requirements.
Q10: Can you supply BOP hose for accumulator units?
Yes. We can supply BOP control hose assemblies for accumulator units, control manifolds and hydraulic control lines according to confirmed specifications.
Q11: Can you supply BOP hose for offshore rigs?
Yes. We can supply API 16D BOP hose assemblies for land rigs, offshore rigs and well control equipment packages, according to confirmed technical requirements.
| Nominal inner dia.(mm) | Outer dia.of hose assembly (mm) | Operating Pressure (MPa) | Min.burst Pressure (MPa) | Min. bending radius (mm) | Thread | Operating time (min)with fire-resisting at 750℃ | |
|---|---|---|---|---|---|---|---|
| Normal | Limit | ||||||
| 19 | 44 | 35 | 105 | 280 | NPT LP | 5 | 25 |
| 50 | 70 | 175 | |||||
| 22 | 47 | 35 | 105 | 320 | |||
| 53 | 70 | 175 | |||||
| 25 | 50 | 35 | 105 | 360 | |||
| 56 | 70 | 175 | |||||
| 31.5 | 56 | 35 | 105 | 460 | |||
| 62 | 70 | 175 | |||||
| 38 | 63 | 35 | 105 | 560 | |||
| 69 | 70 | 175 | |||||